Utilizing the latest in technology bender equipment ensures that electrical ground faults are detected and located fast and automatically in compliance with the latest standards and code requirements.
Isolated power supply for hospital.
Isolated power panels for medical facilities are designed to provide ungrounded service for a variety of hospital applications.
Reduce electric shock hazard.
With decades of experience in protecting patients and caregivers in the healthcare industry we custom design and manufacture isolated power systems for many locations within hospitals surgery centers and other critical care medical care facilities.
Ips isolated power supply 8kva germany.
The uninterruptible power is very important for medical issues and hospitals.
These systems also eliminate the danger of an electric shock to patients who may be more susceptible to leakage current and unable to move in their bed.
Because it is all about the human health directly in this fields.
For more than 50 years pg lifelink has been providing isolated power systems to healthcare facilities.
These systems also eliminate the danger of an electric shock to patients who may be more susceptible to leakage current and unable to move in their b.
These isolation power systems remain in operation in the event of a single line to ground fault situation.
To provide ungrounded single phase power to patient care areas deemed as wet procedure locations so as to.
That s why speacial isolated ups medical ups solutions are developed to prevent this kind of problems.
An isolation power system provides an ungrounded electrical service for various applications within a hospital or a medical office building.
Isolated power system purpose.
Bender isolated power panels provide isolated power to electrical systems in operating rooms and other critical care areas.
Isolated power supply system within each ips system an integrated tcp ip transmission control protocol internet protocol web server is provided so that all ips information is accessible without any additional equipment across the hospital network using a standard browser such as ms internet explorer google chrome.
Limits ground fault current typically to less than 5 ma practically eliminates the danger of massive electrical shocks macro shock to patients or personnel from ground fault however does not protect against micro shock current levels that can affect cardiac patients during ground fault.
Back box requires a 14 inch deep wall each panel supplies up to 16 120 v circuits plus one 30 a 208 v circuit for equipment such as a laser receptacle.
Dual voltage panels supply both 120 v and 208 v isolated power to an operating room.
The alternate power source will consist of two or more engine generator sets designed to provide electrical power for hospital essential electrical systems plus.
They supply uninterrupted power in the event of one line to ground fault while eliminating the danger of electrical shock.
N isolation power system provides an ungrounded elec trical service for various applications within a hospital or a medical office building.
These isolation power sys tems remain in operation in the event of a single line to ground fault situation.